(800) 947-1464
Customer Service
(800) 947-1464
Customer Service
(800) 947-1464
Customer Service
Added to Basket
  • About Us
  • Made in America
  • Contact Us
  • GSA Advantage
  • Site Map

Signal Conflict Monitor - NEMA SMU-12/16

Signal Conflict Monitor - NEMA SMU-12/16

$0.00

Product Code: SMU-12/16
Made in USA #1Icon #5

Product Information
Specification

All Signal Conflict Monitors meet or exceed NEMA TS1-1989 (R1994) standards for 12 Channel Conflict Monitor Units. SMU-12 cost saving benefits include easier monitor programming, reduced litigation, improved efficiency for intersection operation, accurate record keeping and data logging. NEMA Signal Conflict Monitors come with a two year warranty and made in the United States.

Features:

* Flash Time adjustable from 1 to 16 seconds
* RESET keypad prevents defeating signal monitor operation if RESET is taped down
* Conflicting Green, Yellow, or Walk on any two or more non-compatible channels
* Microprocessor based design
* Real Time Clock
* Internal Watch Dog flash transfer hardware circuit
* Three Event Logs, each of 100 records, retained through power failure
* Enhanced Monitoring
* Displaying permissive programming on front panel display and Personal/Laptop Computer
* 4 line x 20 character back-lit extended temperature range LCD display for clear display of information

Specifications:

Operating Voltage & Load:
89 - 135 VAC. 60+/-3 Hertz 1 Amp SLO-BLO Fuse
Temperature Range:
-30 °F to 165 °F.
Displayed Information:
All active channels on 4 line x 20 character LCD.
Channels Monitored:
12 Channels with 4 inputs / channel (Green, Yellow, Walk, Red / Don't Walk).
16 Load Sensing Switch positions with 2 inputs / channel (input/output status, current).
2 Malfunction Response Module positions with 2 inputs / channel (output status, current).

Options:

RS232 Communications (Specify RS232 Option)

Complete real-time RS232 communications is provided. Retrieval of monitor information and monitor function selections may be made through the front panel key pad or the RS232 port. The baud rate for communication is capable of being set from 400 to 9600 baud.

Event Monitor/Alarm Reporting/Special Function Controller Communications

Two separate contact closures are provided which can drive two alarm or special function inputs. One contact closure automatically reports any function which has ben programed to be monitored as a MESSAGE when such an event is detected. The second contact closure automatically reports any BULB OUT/HIGH CURRENT event when such an event is detected. (BULB OUT/HIGH CURRENT event reporting requires the installation of the Load Management System)

Security Code Protection (Specify -SC Option)

A Security Code of four digits may be used to restrict entry into any monitor command which would result in changing of monitor operation or clearing of stored events. The Security Code is not needed to read stored information.

External Modem Communications (Specify - EM Option)

Complete real-time RS232 communications through a Hayes modem is provided. Retrieval of stored event records and setup information is possible through a Hayes modem from a remote location using a telephone line. Monitor function selections may be made through the Hayes modem. An RS232 port is provided on the monitor with this option.

Systems Communication (Contact U.S. Barricades prior to Specification)

Complete real-time RS232 communications through the controller unit using a shared communications protocol is provided. Retrieval of setup information is possible through the front panel key pad or through this Systems RS232 port. Monitor function selections may be made through the front panel key pad or the RS232 port.The baud rate for communication is capable of being set from 400 to 9600 baud. This option requires a user-defined communications protocol.

Product CodeSMU-12/16
ManufacturerTSC
ConditionNew

This field is required.
Top